Thermal performance verification for the JEM MAXI loop heat pipe and radiator system

Hiroki Nagai, Shiro Ueno

研究成果: Paper査読

抄録

The thermal performance of the Loop Heat Pipe and Radiator System (LHPRS) has been verified in the thermal vacuum testing. LHPRS is used as the heat transport system to reject heat from the Monitor of All-sky X-ray Image (MAXI). Since this LHPRS was designed exclusively for the MAXI system, it has two-condensers in parallel connected to a common evaporator. Since it is possible that the heat transportation deviates to one condenser only, it had to be investigated how the double condensers affect the LHPRS performance under various conditions. Thermal vacuum testing was conducted for the engineering model of the MAXI/LHPRS. In this paper, the test result and performance verification of the MAXI/LHPRS are described.