Thermal conductivity measurements of liquid CO2 by the transient short-hot-wire method

Daisuke Tomida, Tsuyoshi Odashima, Chiaki Yokoyama

研究成果: Article査読

1 被引用数 (Scopus)

抄録

Experimental results for the thermal conductivities of liquid CO2 are reported. The thermal conductivities were measured by a transient short-hot-wire method. Experimental temperatures ranged from 273.8 to 294.5 K, and pressures from 4.0 to 15.0MPa. The uncertainty of the reported thermal conductivity data was estimated to be within ±3.0%. The experimental data were compared with calculated values from the REFPROP 8.0.

本文言語English
ページ(範囲)429-431
ページ数3
ジャーナルkagaku kogaku ronbunshu
36
5
DOI
出版ステータスPublished - 2010 11 9

ASJC Scopus subject areas

  • Chemistry(all)
  • Chemical Engineering(all)

フィンガープリント 「Thermal conductivity measurements of liquid CO<sub>2</sub> by the transient short-hot-wire method」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。