Thermal behavior of a double-condenser design LHP for Monitor of All-sky X-ray Image

Miki Muto, Masahide Murakami, Hiroki Nagai, Shiro Ueno, Masaru Matsuoka

研究成果: Conference article査読

4 被引用数 (Scopus)

抄録

A loop heat pipe (LHP) is used as the heat transport device to reject heat from the Monitor of All-sky X-ray Image (MAXI). Since this LHP was designed exclusively for the MAXI system, it is different from conventional LHPs in configuration, a double-condenser design. We experimentally investigated the effects of the particular design of this LHP on the heat transfer performance by using the LHP Ground Test Unit (GTU) on the ground. The steady heating experiment was carried out to investigate the effective thermal conductance through the comparison with the prediction. When the two condensers were cooled at different temperatures under a steady heating condition, a quasi-periodic temperature oscillation was observed in the evaporator and accumulator area.

本文言語English
ジャーナルSAE Technical Papers
DOI
出版ステータスPublished - 2002 1月 1
外部発表はい
イベント32nd International Conference on Environmental Systems - San Antonio, TX, United States
継続期間: 2002 7月 152002 7月 18

ASJC Scopus subject areas

  • 自動車工学
  • 安全性、リスク、信頼性、品質管理
  • 汚染
  • 産業および生産工学

フィンガープリント

「Thermal behavior of a double-condenser design LHP for Monitor of All-sky X-ray Image」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル