Successful catheter intervention for deep vein thrombosis due to inferior vena cava stenosis after retrieval of a temporary inferior vena cava filter

Yusuke Hattori, Akihiro Tsuji, Takeshi Ogo, Jin Ueda, Shigefumi Fukui, Satoshi Yasuda

研究成果: Article査読

抄録

Inferior vena cava (IVC) stenosis is a well-known complication of the IVC filter. However, there are no previous reports of IVC stenosis caused by a temporary IVC filter. In this case report, we describe the case of a 35-year-old man who was referred to our center for the treatment of recurrent proximal deep vein thrombosis (DVT) and severe IVC stenosis that occurred after retrieval of a temporary IVC filter. We performed a catheter-directed thrombolysis and balloon angioplasty. DVT resolved effectively, and his leg symptoms resolved. <Learning objective: Although IVC filter-related stenosis is not common, it should be managed, even when a temporary IVC filter is used. The combination of catheter-directed thrombolysis and balloon angioplasty may be considered for a proximal deep vein thrombosis complicated with IVC stenosis.>

本文言語English
ページ(範囲)22-24
ページ数3
ジャーナルJournal of Cardiology Cases
15
1
DOI
出版ステータスPublished - 2017 1 1
外部発表はい

ASJC Scopus subject areas

  • 循環器および心血管医学

フィンガープリント

「Successful catheter intervention for deep vein thrombosis due to inferior vena cava stenosis after retrieval of a temporary inferior vena cava filter」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル