Reliability evaluation of an wearable consumer optical heart rate monitor

Kenji Tagawa, Kengo Kinoshita

研究成果: Article査読

抄録

Motivation: Over the past few years, activity trackers which can measure everyday steps, energy expenditures, and sleeping time are getting popular. Especially these days, some activity trackers use not only accelerometers but also optical heart rate monitors based on photopletysmography. In this study, we evaluated reliability of an optical heart rate activity tracker during running. Method and Results: Several subjects(n=11, all male) ran 1km on a flat road and we analyzed heart rate errors to check if there was a difference between subjects. We found that some subjects had significantly higher Mean Absolute Error than others(highest MAE,20.54±13.64; average MAE, 8.41±6.47), and there was a strong correlation between each subject’s MAE and the standard deviation of running speed(Pearson’s r=0.87, p<0.001). Conclusion: Optical HR monitors lead to errors when users change their pace of running.

本文言語English
ページ(範囲)601-602
ページ数2
ジャーナルTransactions of Japanese Society for Medical and Biological Engineering
55
Proc
DOI
出版ステータスPublished - 2017 1月 1

ASJC Scopus subject areas

  • 生体医工学

フィンガープリント

「Reliability evaluation of an wearable consumer optical heart rate monitor」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル