Pulsed ECT method for evaluation of pipe wall-thinning of nuclear power plants using magnetic sensor

Shejuan Xie, Toshihiro Yamamoto, Toshiyuki Takagi, Tetsuya Uchimoto

研究成果: Conference contribution

8 被引用数 (Scopus)

抄録

In nuclear power plants, there may happen local wall-thinning on the inner surface of a pipe due to the flow of coolant flowing inside the pipe. Pulsed eddy current testing (pulsed ECT) technology is developed in recent years. Because of its rich frequency components and applicability of large electric current, a pulsed ECT method may show promising capability of detecting and evaluating the defect in the deep region of the material. The aim of this study is to discuss the feasibility of detection and evaluation of local wall-thinning of the bottom surface in one thick layer and also in the lower layer of two-layer structure pipe using a pulsed ECT method. Concerning the large thickness of the specimen, a high sensitive flux gate (FG) sensor has been employed and the corresponding differential exciting mode has been developed to efficiently apply the FG sensor. Experimental results show that this FG sensor combined with differential exciting mode could detect a very small defect that is located in a thick specimen while which could not be detected by Hall sensor.

本文言語English
ホスト出版物のタイトルElectromagnetic Nondestructive Evaluation (XIV)
編集者Tomasz Chady, Stanislaw Gratkowski, Toshiyuki Takagi, Satish S. Udpa
ページ203-210
ページ数8
DOI
出版ステータスPublished - 2011

出版物シリーズ

名前Studies in Applied Electromagnetics and Mechanics
35
ISSN(印刷版)1383-7281
ISSN(電子版)1879-8322

ASJC Scopus subject areas

  • Mechanical Engineering
  • Electrical and Electronic Engineering

フィンガープリント 「Pulsed ECT method for evaluation of pipe wall-thinning of nuclear power plants using magnetic sensor」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル