Production and validation of acoustic field to enhance trapping efficiency of microbubbles by using a matrix array transducer

Naoto Hosaka, Ren Koda, Shinya Onogi, Takashi Mochizuki, Kohji Masuda

研究成果: Article査読

24 被引用数 (Scopus)

抄録

We have developed a new matrix array transducer for controlling the behavior of microbubbles, which is different from that for high-intensity focused ultrasound (HIFU) therapy, in order to emit continuous wave by designing an acoustic field including multiple focal points. In the experiment using a thin-channel model, a wider acoustic field has an advantage for trapping microbubbles. In the experiment using a straight-path model, we have confirmed that a higher concentration of acoustic energy does not result in more aggregates. The dispersion of acoustic energy is important because the trapping performance is affected by the relationship between the shape of the acoustic field and the concentration of the suspension.

本文言語English
論文番号07HF14
ジャーナルJapanese journal of applied physics
52
7 PART 2
DOI
出版ステータスPublished - 2013 7 1

ASJC Scopus subject areas

  • Engineering(all)
  • Physics and Astronomy(all)

フィンガープリント 「Production and validation of acoustic field to enhance trapping efficiency of microbubbles by using a matrix array transducer」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。