On contact conditions in connectors to cause Common Mode radiation

Yu Ichi Hayashi, Yoshiki Kayano, Takaaki Mizuki, Hideaki Sone, Hiroshi Inoue

研究成果: Conference article査読

5 被引用数 (Scopus)

抄録

When contact failure occurs in a connector in a coaxial HF signal transmission line, Common Mode (CM) radiation occurs on the line. We focus on contact conditions in a connector causing CM radiation. The experiments and the simulations verified that the CM radiation increases as contact resistance increases. While the CM current greatly depends on the pattern of distribution of contact resistance at a low resistance, the CM current does not depend on it at a high resistance. It is necessary to keep a distribution of four or more contact spots symmetrical.

本文言語English
論文番号4652102
ジャーナルIEEE International Symposium on Electromagnetic Compatibility
2008-January
DOI
出版ステータスPublished - 2008
イベント2008 IEEE International Symposium on Electromagnetic Compatibility, EMC 2008 - Detroit, MI, Germany
継続期間: 2008 8月 182008 8月 22