Measurement of core loss in single sheet tester

Teruyuki Tamaki, Keisuke Fujisaki, Masao Yabumoto, Naoya Hamada

研究成果: Article査読

抄録

The core loss measured with the indirect magnetizing single sheet tester (SST) (in which a sample is placed between yokes and is indirectly magnetized by the yokes magnetized by magnetizing coils) roughly corresponds with that measured with the direct magnetizing SST used as standard (in which a sample is placed inside a magnetizing coil and is directly magnetized by the magnetizing coil). Both the SSTs have the B coil and the H coil whose widths are the same as the sample width. However, the core loss measured with the indirect magnetizing SST using the small size of the B coil and the H coil is much different from that measured with the direct magnetizing SST.

本文言語English
ページ(範囲)14-17
ページ数4
ジャーナルPrzeglad Elektrotechniczny
83
4
出版ステータスPublished - 2007 5月 14