Low temperature ductility loss and microstructural evolution of vanadium-titanium-chromium-silicon type alloy after helium ion implantation

Manabu Satou, Toshinori Chuto, Akira Hasegawa, Katsunori Abe

研究成果: Article

1 被引用数 (Scopus)

抄録

Vanadium alloy as candidate structural material would be used at temperatures ranging above 600°C. However, the components might be exposed to low temperature and low neutron flux irradiation during transient operation such as start-up and shutdown period of the reactor. Helium generation also has a possibility to affect the irradiation behavior of the alloy at the low-temperature. Helium effect on loss of ductility at low-temperature neutron irradiation for vanadium alloy was pointed out from the results of tensile tests using various combinations of helium charging and neutron irradiation. It is possible so far that pre-implantation at ambient temperature increases radiation hardening of the vanadium alloy after irradiation at 400°C. From the viewpoint of low-temperature and low-flux irradiation behavior of vanadium alloy, to clarify the helium effect on microstructure evolution, especially small complexes of interstitial impurity and irradiation defect is needed.

本文言語English
ページ(範囲)420-423
ページ数4
ジャーナルUnknown Journal
40
5
DOI
出版ステータスPublished - 1999 5

ASJC Scopus subject areas

  • Engineering(all)

フィンガープリント 「Low temperature ductility loss and microstructural evolution of vanadium-titanium-chromium-silicon type alloy after helium ion implantation」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。