Iron and manganese removal by a membrane filtration system

Y. Jimbo, K. Goto

研究成果: Article査読

4 被引用数 (Scopus)

抄録

The design standards of the iron and manganese removal system by membrane filtration were investigated. The membrane filtration after pre-chlorination could remove iron completely and could remove around 70% of manganese. In the case of manganese concentration being more than 0.05 mg/l, the membrane filtration could remove them completely after the deposition in the oxidation tank. The concentrations of iron and manganese were reduced more than 90% by the oxidation tank and were reduced until under the detection limit after the membrane filtration. The economic comparisons between the rapid sand filtration system and this membrane filtration system in a small capacity and a middle capacity were investigated. The 15 years total costs of the membrane filtration system were estimated to be smaller than or around equal to the rapid sand filtration system in both capacities.

本文言語English
ページ(範囲)357-364
ページ数8
ジャーナルWater Science and Technology: Water Supply
1
5-6
DOI
出版ステータスPublished - 2001 1 1

ASJC Scopus subject areas

  • 水の科学と技術

フィンガープリント

「Iron and manganese removal by a membrane filtration system」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル