Infrared Camera onboard ASTRO-F

T. Wada, S. Fujita, H. Kataza, W. Kim, I. Maeda, H. Matsuhara, T. Matsumoto, H. Murakami, K. Uemizu, H. Watarai, D. Ishihara, T. Negishi, T. Onaka, Takafumi Ootsubo, H. Takeyama, M. Ueno

研究成果: Article査読

6 被引用数 (Scopus)

抄録

The design and the current development status of the Infrared Camera (IRC) onboard ASTRO-F is described. The IRC is designed for wide field imaging and slit-less spectroscopic observations at near- and mid-infrared wavelengths. The IRC consists of three channels, NIR, MIR-S and MIR-L, which cover wave-lengths of 2-5, 5-12 and 12-26 micron, respectively. All of them consist of refractive optics. State-of-the-art large format array detectors are placed at the focal plane. Each channel has 10 × 10 arcmin wide field-of-view with diffraction-limited spatial resolution of 70 cm aperture of ASTRO-F telescope at wavelengths over 5 micron. We plan to have more than 7000 pointing observations dedicated for the IRC. The observational time of each pointing is limited to 500 seconds because of its low earth sun-synchronous polar orbit. The 5 sigma sensitivity of one pointing observation is estimated to be 2, 30 and 120 micro-Jy at 5, 9, 20 micron bands, respectively. Fabrication of the prototype model has been completed, and the performance tests are underway.

本文言語English
ページ(範囲)2111-2116
ページ数6
ジャーナルAdvances in Space Research
30
9
DOI
出版ステータスPublished - 2002 1 1

ASJC Scopus subject areas

  • Aerospace Engineering
  • Astronomy and Astrophysics
  • Geophysics
  • Atmospheric Science
  • Space and Planetary Science
  • Earth and Planetary Sciences(all)

フィンガープリント 「Infrared Camera onboard ASTRO-F」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル