TY - JOUR
T1 - Influence of myopic disc shape in a classification program of the Heidelberg retina tomograph
AU - Yamazaki, Yoshio
AU - Yoshikawa, Keiji
AU - Kunimatsu, Shiho
AU - Koseki, Nobuyuki
AU - Suzuki, Yasuyuki
AU - Matsumoto, Shun
AU - Araie, Makoto
N1 - Copyright:
Copyright 2012 Elsevier B.V., All rights reserved.
PY - 1999/5
Y1 - 1999/5
N2 - Purpose: We investigated the influence of myopic disc shape on the diagnostic capability of a glaucoma diagnostic software (classification program) of the Heidelberg retina tomograph (HRT). Subjects: 66 eyes of 66 normal subjects and 78 eyes of 78 patients with open-angle glaucoma were studied. The criterion of glaucoma was a visual field defect appearing between Aulhorn classification stage II and stage V regardless of the maximum intraocular pressure value. Methods: The subjects were divided into eyes with a myopic disc and those with a non-myopic disc on the basis of stereo disc fundus photographs without considering the refractive errors. Agreement between the classification program and the clinical diagnosis was evaluated by the calculation of sensitivity, specificity, and diagnostic precision, and the influence of the disc shape on HRT disc shape parameters was also evaluated. Results: Sensitivity, specificity, and diagnostic precision of the classification program were 83%, 95%, and 89% in the eyes with a non-myopic disc, and 71%, 96%, and 83% in the eyes with a myopic disc, respectively. Rim volume, height variation contour, mean RNFL (retinal nerve fiber layer) thickness, and RNFL cross section area were significantly larger in the eyes with a myopic disc than in those with a non-myopic disc regardless of the clinical diagnosis. Conclusion: The classification program should be modified to adjust to a myopia-like disc shape in order to improve the capability of the glaucoma predictive diagnosis.
AB - Purpose: We investigated the influence of myopic disc shape on the diagnostic capability of a glaucoma diagnostic software (classification program) of the Heidelberg retina tomograph (HRT). Subjects: 66 eyes of 66 normal subjects and 78 eyes of 78 patients with open-angle glaucoma were studied. The criterion of glaucoma was a visual field defect appearing between Aulhorn classification stage II and stage V regardless of the maximum intraocular pressure value. Methods: The subjects were divided into eyes with a myopic disc and those with a non-myopic disc on the basis of stereo disc fundus photographs without considering the refractive errors. Agreement between the classification program and the clinical diagnosis was evaluated by the calculation of sensitivity, specificity, and diagnostic precision, and the influence of the disc shape on HRT disc shape parameters was also evaluated. Results: Sensitivity, specificity, and diagnostic precision of the classification program were 83%, 95%, and 89% in the eyes with a non-myopic disc, and 71%, 96%, and 83% in the eyes with a myopic disc, respectively. Rim volume, height variation contour, mean RNFL (retinal nerve fiber layer) thickness, and RNFL cross section area were significantly larger in the eyes with a myopic disc than in those with a non-myopic disc regardless of the clinical diagnosis. Conclusion: The classification program should be modified to adjust to a myopia-like disc shape in order to improve the capability of the glaucoma predictive diagnosis.
KW - Classification program
KW - Heidelberg retina tomograph
KW - Myopic disc change
UR - http://www.scopus.com/inward/record.url?scp=0033198782&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033198782&partnerID=8YFLogxK
M3 - Article
C2 - 10580661
AN - SCOPUS:0033198782
VL - 103
SP - 392
EP - 398
JO - Nippon Ganka Gakkai zasshi
JF - Nippon Ganka Gakkai zasshi
SN - 0029-0203
IS - 5
ER -