抄録
We proposed a new approach to identify the frequencies of droplet rotation and m = ±2 oscillation that degrade the accuracy of surface tension measurement by an oscillating droplet method. Frequencies of droplet rotation and m = ±2 oscillation can be identified by a phase unwrapping analysis of time dependence of the deflection angle for the maximum diameter of the droplet image observed from above. The present method was validated, using test data with given frequencies.
本文言語 | English |
---|---|
ページ(範囲) | 421-430 |
ページ数 | 10 |
ジャーナル | Heat Transfer - Asian Research |
巻 | 37 |
号 | 7 |
DOI | |
出版ステータス | Published - 2008 12月 1 |
外部発表 | はい |
ASJC Scopus subject areas
- 凝縮系物理学
- 流体および伝熱