Hysteresis of pressure-sensitive paint in cryogenic wind tunnels

Yasuhiro Egami, Yoshimi Iijima, Keisuke Asai

研究成果: Article

抜粋

The causes of disagreement between a priori and in situ results of Pressure-Sensitive Paint (PSP) measurements in cryogenic wind tunnels have been investigated. Systematic experiments were conducted in the JAXA 0.1-m cryogenic wind tunnel to clarify the factors of the disagreement. In the experiments, the influence of total and static temperatures, and oxygen concentrations in the cryogenic wind tunnel on PSP results were evaluated. Consequently, it was detected that this disagreement originates in the difference between a total pressure-change calibration and a partial oxygen pressure-change calibration, and the hysteresis of luminescent intensity during pressurization and depressurization process at low temperatures less than 110 K.

元の言語English
ページ(範囲)254-258
ページ数5
ジャーナルNihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
76
発行部数762
DOI
出版物ステータスPublished - 2010 2
外部発表Yes

ASJC Scopus subject areas

  • Condensed Matter Physics
  • Mechanical Engineering

フィンガープリント Hysteresis of pressure-sensitive paint in cryogenic wind tunnels' の研究トピックを掘り下げます。これらはともに一意のフィンガープリントを構成します。