TY - JOUR
T1 - High range resolution ultrasonographic vascular imaging using frequency domain interferometry with the capon method
AU - Taki, Hirofumi
AU - Taki, Kousuke
AU - Sakamoto, Takuya
AU - Yamakawa, Makoto
AU - Shiina, Tsuyoshi
AU - Kudo, Motoi
AU - Sato, Toru
PY - 2012/2
Y1 - 2012/2
N2 - For high range resolution ultrasonographic vascular imaging, we apply frequency domain interferometry with the Capon method to a single frame of in-phase and quadrature (IQ) data acquired using a commercial ultrasonographic device with a 7.5 MHz linear array probe. In order to tailor the adaptive beamforming algorithm for ultrasonography we employ four techniques: frequency averaging, whitening, radio-frequency data oversampling, and the moving average. The proposed method had a range resolution of 0.05 mm in an ideal condition, and experimentally detected the boundary couple 0.17 mm apart, where the boundary couple was indistinguishable from a single boundary utilizing a B-mode image. Further, this algorithm could depict a swine femoral artery with a range beam width of 0.054 mm and an estimation error for the vessel wall thickness of 0.009 mm, whereas using a conventional method the range beam width and estimation error were 0.182 and 0.021 mm, respectively. The proposed method requires 7.7 s on a mobile PC with a single CPU for a 1\times 3~{\hbox {cm}} region of interest. These findings indicate the potential of the proposed method for the improvement of range resolution in ultrasonography without deterioration in temporal resolution, resulting in enhanced detection of vessel stenosis.
AB - For high range resolution ultrasonographic vascular imaging, we apply frequency domain interferometry with the Capon method to a single frame of in-phase and quadrature (IQ) data acquired using a commercial ultrasonographic device with a 7.5 MHz linear array probe. In order to tailor the adaptive beamforming algorithm for ultrasonography we employ four techniques: frequency averaging, whitening, radio-frequency data oversampling, and the moving average. The proposed method had a range resolution of 0.05 mm in an ideal condition, and experimentally detected the boundary couple 0.17 mm apart, where the boundary couple was indistinguishable from a single boundary utilizing a B-mode image. Further, this algorithm could depict a swine femoral artery with a range beam width of 0.054 mm and an estimation error for the vessel wall thickness of 0.009 mm, whereas using a conventional method the range beam width and estimation error were 0.182 and 0.021 mm, respectively. The proposed method requires 7.7 s on a mobile PC with a single CPU for a 1\times 3~{\hbox {cm}} region of interest. These findings indicate the potential of the proposed method for the improvement of range resolution in ultrasonography without deterioration in temporal resolution, resulting in enhanced detection of vessel stenosis.
KW - Adaptive signal processing
KW - Capon method
KW - frequency domain interferometry
KW - ultrasonic imaging
KW - vascular ultrasound
UR - http://www.scopus.com/inward/record.url?scp=84856711301&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84856711301&partnerID=8YFLogxK
U2 - 10.1109/TMI.2011.2170847
DO - 10.1109/TMI.2011.2170847
M3 - Article
C2 - 21984496
AN - SCOPUS:84856711301
SN - 0278-0062
VL - 31
SP - 417
EP - 429
JO - IEEE Transactions on Medical Imaging
JF - IEEE Transactions on Medical Imaging
IS - 2
M1 - 6035979
ER -