Forward-nulling passive millimeterwave imaging using cooling dielectric tube

Hiroyasu Sato, Kohei Kuriyama, Kunio Sawaya

研究成果: Article査読

3 被引用数 (Scopus)

抄録

In order to improve the detection performance in passive millimeter-wave (PMMW) imaging, a new method forwarding a null in the direction of human body and objects is proposed. The forward-nulling PMMW imaging using a dielectric tube occupied by cooling water placed near the focus line of a parabolic cylinder are performed. It is shown experimentally that the contrast between human body and conducting objects such as a conducting plate and a conducting sphere is improved by the presence of the cooling dielectric tube and parabolic cylinder.

本文言語English
ページ(範囲)1627-1634
ページ数8
ジャーナルIEICE Transactions on Electronics
E95-C
10
DOI
出版ステータスPublished - 2012 10月