Experimental tests of a musculoskeletal model of the elbow joint for FES applications

Takashi Watanabe, Tsuneyuki Nozawa, Gwang Moon Eom, Shigeo Ohba, Ryoko Futami, Nozomu Hoshimiya, Yasunobu Handa

研究成果: Conference article査読

抄録

Computer model prediction of motions developed by functional electrical stimulation (FES) can be effective for clinical applications. The musculoskeletal model that respond to electrical stimulation is necessary for the model prediction. In this paper, a musculoskeletal model of the elbow joint was tested experimentally on a normal subject with surface electrode stimulation. In the musculoskeletal model, the musculotendon guide that reflects geometrical arrangement of muscles was adopted. Parameters in the muscle model were adapted to the subject based on the force measured under the isometric condition. Output of the tuned model agreed well with experimental results of the single muscle stimulation at high amplitude of stimulation and results of the simultaneous antagonistic stimulation in some stimulus conditions.

本文言語English
ページ(範囲)2594-2597
ページ数4
ジャーナルAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
5
出版ステータスPublished - 1998 12 1
イベントProceedings of the 1998 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Part 4 (of 6) - Hong Kong, China
継続期間: 1998 10 291998 11 1

ASJC Scopus subject areas

  • Signal Processing
  • Biomedical Engineering
  • Computer Vision and Pattern Recognition
  • Health Informatics

フィンガープリント 「Experimental tests of a musculoskeletal model of the elbow joint for FES applications」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル