T1 - Evaluation of long-term mechanical and biological biocompatibility of low-cost β-type Ti-Mn alloys for biomedical applications
AU - Cho, Ken
AU - Niinomi, Mitsuo
AU - Nakai, Masaaki
AU - Santos, Pedro Femandes
AU - Liens, Alethea Morgane
AU - Ikeda, Masahiko
AU - Hattori, Tomokazu
PY - 2015
Y1 - 2015
N2 - To evaluate the long-term mechanical biocompatibility of Ti-Mn alloys, the microstructures, Young's moduli, and tensile and fatigue properties of the solutionized Ti-8Mn and Ti-13Mn were investigated. In addition, to evaluate the long-term biological biocompatibility of Ti-Mn alloys, the bone formability of the solutionized Ti-12Mn implant was evaluated by animal testing. The solutionized Ti-8Mn and Ti-13Mn consist of equiaxed β-grains with diameters of approximately 420 m and 430 μm, respectively. Moreover, the solutionized Ti-8Mn also contains an athermal co phase. The 0.2 % proof stress (00.2), tensile strength (OB), and elongation of the solutionized Ti-8Mn are 1148 MPa, 1184 MPa, and 2%, respectively. The 00.2 and OB decrease to 915 MPa and 953 MPa, respectively, and the elongation increases to 7% for the solutionized Ti-13Mn. The higher strength and significantly lower elongation of the solutionized Ti-8Mn are attributed to precipitation of an athermal co phase. The fatigue strength of the solutionized Ti-8Mn is comparable to that of the aged Ti-6A1-4V ELI in the low-cycle fatigue life region. The striation widths of the solutionized Ti-8Mn and Ti-13Mn are 2.4 m and 7.8 m, respectively. The smaller striation width of the solutionized Ti-8Mn indicates that the crack propagation rate in the solutionized Ti-8Mn is smaller than that in the solutionized Ti-13Mn. The relative bone contact ratio of the solutionized Ti-12Mn increases from 11% to 29% when the implant period increases from 12 to 52 weeks. The relative bone contact ratios of the solutionized Ti-12Mn implant and the commercially pure Ti implant are almost identical for all implantation periods.
AB - To evaluate the long-term mechanical biocompatibility of Ti-Mn alloys, the microstructures, Young's moduli, and tensile and fatigue properties of the solutionized Ti-8Mn and Ti-13Mn were investigated. In addition, to evaluate the long-term biological biocompatibility of Ti-Mn alloys, the bone formability of the solutionized Ti-12Mn implant was evaluated by animal testing. The solutionized Ti-8Mn and Ti-13Mn consist of equiaxed β-grains with diameters of approximately 420 m and 430 μm, respectively. Moreover, the solutionized Ti-8Mn also contains an athermal co phase. The 0.2 % proof stress (00.2), tensile strength (OB), and elongation of the solutionized Ti-8Mn are 1148 MPa, 1184 MPa, and 2%, respectively. The 00.2 and OB decrease to 915 MPa and 953 MPa, respectively, and the elongation increases to 7% for the solutionized Ti-13Mn. The higher strength and significantly lower elongation of the solutionized Ti-8Mn are attributed to precipitation of an athermal co phase. The fatigue strength of the solutionized Ti-8Mn is comparable to that of the aged Ti-6A1-4V ELI in the low-cycle fatigue life region. The striation widths of the solutionized Ti-8Mn and Ti-13Mn are 2.4 m and 7.8 m, respectively. The smaller striation width of the solutionized Ti-8Mn indicates that the crack propagation rate in the solutionized Ti-8Mn is smaller than that in the solutionized Ti-13Mn. The relative bone contact ratio of the solutionized Ti-12Mn increases from 11% to 29% when the implant period increases from 12 to 52 weeks. The relative bone contact ratios of the solutionized Ti-12Mn implant and the commercially pure Ti implant are almost identical for all implantation periods.
UR - http://www.scopus.com/inward/record.url?scp=84947236120&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84947236120&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84947236120
T3 - Ceramic Transactions
SP - 3
EP - 12
BT - Biomaterials Science
A2 - Bose, Susmita
A2 - Bandyopadhyay, Amit
A2 - Narayan, Roger
PB - American Ceramic Society
T2 - Next Generation Biomaterials and Surface Properties of Biomaterials Symposia - Materials Science and Technology 2014 Conference, MS and T 2014
Y2 - 12 October 2014 through 16 October 2014
ER -