In this paper characteristics of backlayering of thermal fumes induced by emergency fires in tunnels is studied. The critical velocity used to prevent the thermal fume and smoke from backlayering upwind is firstly evaluated by this study using 3 dimensional LES turbulence model. Simulation result shows that under low heat release rate of fire, the critical velocity increases linearly when heat release rate increases, but this dependent relation will become weak under high heat release rate. Result also shows a supercritical velocity valued 2.5-2.7 m/s exists, which agrees to the conventional experimental studies.