TY - CHAP
T1 - Evaluation of circumferential crack location in pipes by electromagnetic waves
AU - Abbasi, Kavoos
AU - Ito, Satoshi
AU - Hashizume, Hidetoshi
AU - Yuki, Kazuhisa
PY - 2007/12/1
Y1 - 2007/12/1
N2 - Crack detection is one of the most important issues in large component such as nuclear power plant. A NDT method using electromagnetic waves has strong possibility for crack detection in large pipes. In this study, TM01-mode of electromagnetic wave is used for detecting a circumferential crack and time of flight (TOF) of the electromagnetic wave in straight pipe with crack is evaluated to determine the crack location.
AB - Crack detection is one of the most important issues in large component such as nuclear power plant. A NDT method using electromagnetic waves has strong possibility for crack detection in large pipes. In this study, TM01-mode of electromagnetic wave is used for detecting a circumferential crack and time of flight (TOF) of the electromagnetic wave in straight pipe with crack is evaluated to determine the crack location.
KW - Electromagnetic wave
KW - Nondestructive testing
KW - Time of flight (TOF)
KW - circumferential crack
KW - inspected pipe
UR - http://www.scopus.com/inward/record.url?scp=70349180041&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=70349180041&partnerID=8YFLogxK
M3 - Chapter
AN - SCOPUS:70349180041
SN - 9781586037529
T3 - Studies in Applied Electromagnetics and Mechanics
SP - 117
EP - 124
BT - Electromagnetic Nondestructive Evaluation (X)
A2 - Takahashi, Seiki
A2 - Kikuchi, Hiroaki
ER -