Electrochemical behavior of cast Ti-Ag alloys

Masatoshi Takahashi, Masafumi Kikuchi, Yukyo Takada, Toru Okabe, Osamu Okuno

研究成果: Article査読

22 被引用数 (Scopus)

抄録

Anodic polarization tests were performed in 0.9% NaCl and 1% lactic acid solutions to characterize the relationship between the corrosion behavior and the microstructures of cast Ti-Ag (5-40% Ag) alloys. The anodic polarization curves for the Ti-Ag alloys up to 17.5% Ag were similar to those for pure titanium in both solutions. On the other hand, an abrupt increase in the current density was observed for the alloys with more than 20% Ag in the NaCl solution and with more than 27.5% Ag in the lactic acid solution. The microstructures of the corroded alloy surfaces indicated the deterioration of precipitated intermetallic compounds along the grain boundaries. The Ti-Ag alloys up to 17.5% Ag had excellent corrosion resistance similar to that of pure titanium. The alloys with 20-25% Ag may be also used as dental alloys, since they passivated again immediately after preferential dissolution in the NaCl solution.

本文言語English
ページ(範囲)516-523
ページ数8
ジャーナルDental materials journal
25
3
DOI
出版ステータスPublished - 2006

ASJC Scopus subject areas

  • Ceramics and Composites
  • Dentistry(all)

フィンガープリント 「Electrochemical behavior of cast Ti-Ag alloys」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。