Effect of mabuterol on tracheal mucociliary clearance of magnetized iron particles in anesthetized dogs

M. Nakamura, M. Yamaya, T. Fukushima, K. Sekizawa, H. Sasaki, T. Takishima

研究成果: Article査読

2 被引用数 (Scopus)

抄録

We studied the effect of mabuterol on the tracheal mucociliary clearance of magnetized iron particles in anesthetized dogs. A catheter was inserted directly into the trachea through the mouth and 0.05 ml of saline solution with 30 mg of Fe3O4 was instilled into the trachea. After magnetization from outside the chest wall, the remanent magnetic field (RMF) strength generated in the trachea was sequentially measured with a flux-gate magnetometer. The decay of RMF immediately after sequential magnetization showed a clearance of Fe3O4 particles. Mabuterol (10 μg/kg) increased clearance as much as isoproterenol (10 μg/kg) 30 min after intravenous injection relative to control measurement (p<0.01). These results suggest that mabuterol is useful to promote clearance.

本文言語English
ページ(範囲)33-36
ページ数4
ジャーナルRespiration
58
1
DOI
出版ステータスPublished - 1991

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine