Dry-contact technique for high-resolution ultrasonic imaging

Hironori Tohmyoh, Masumi Saka

研究成果: Article査読

25 被引用数 (Scopus)

抄録

To accomplish a high-resolution ultrasonic imaging without wetting a sample, the efficiency of the dry-contact ultrasonic transmission is discussed. In this study, a dry-contact interface is formed on a sample by inserting a thin film between water and a sample, and the pressure is working on the interface by evacuating the air between the film and the sample. A model of dry-contact ultrasonic transmission is presented to assess the signal loss accompanied with the transmission. From the determination of the signal loss caused by the transmission using various films, it was found that the higher frequency ultrasound is transmitted effectively into the sample by selecting an optimum film, which can keep the displacement continuity between the film and the sample during ultrasonic transmission. At last, ultrasonic imaging with the sufficient signal-to-noise ratio (SNR) and high lateral resolution was performed on the delamination in a package and the jointing interface of the ball-grid-array package without wetting the packages.

本文言語English
ページ(範囲)661-667
ページ数7
ジャーナルIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
50
6
DOI
出版ステータスPublished - 2003 6 1

ASJC Scopus subject areas

  • Instrumentation
  • Acoustics and Ultrasonics
  • Electrical and Electronic Engineering

フィンガープリント 「Dry-contact technique for high-resolution ultrasonic imaging」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。