Development of a multi-Fourier-transform interferometer: Imaging experiments in millimeter and submillimeter wave bands

Izumi S. Ohta, Makoto Hattori, Hiroshi Matsuo

研究成果: Article査読

18 被引用数 (Scopus)

抄録

We have developed a millimeter and submillimeter Michelson-type bolometric interferometer based on a Martin-Puplett-type Fourier-transform spectrometer named multi-Fourier-transform interferometer (MuFT). We have succeeded in proving that the MuFT is capable of performing broadband imaging observations as theoretically proposed by our previous paper (OHM) [Appl. Opt. 45, 2576 (2006)]. We succeeded in acquiring the mutual coherence signal for an extended source in broadband. By analyzing the obtained mutual coherence signal following the formula proposed in OHM, 2D source images for each wavenumber from 5 cm-1 (150 GHz) to 35 cm-1 (1.05 THz) with a wavenumber interval of 0.4 cm-1 (12 GHz) were successfully extracted. The large dynamic range advantage of the MuFT proposed in OHM was confirmed experimentally.

本文言語English
ページ(範囲)2881-2892
ページ数12
ジャーナルApplied optics
46
15
DOI
出版ステータスPublished - 2007 5月 20

ASJC Scopus subject areas

  • 原子分子物理学および光学
  • 工学(その他)
  • 電子工学および電気工学

フィンガープリント

「Development of a multi-Fourier-transform interferometer: Imaging experiments in millimeter and submillimeter wave bands」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル