DC potential-drop technique for the evaluation of 3-D back-wall cracks in steel structures

S. Reaz Ahmed, Masumi Saka, Fumio Takeo

研究成果: Article査読

2 被引用数 (Scopus)

抄録

A direct-current potential-drop NDE technique has been developed for the evaluation of a 3-D back-wall crack in thick-walled structures. The measuring system contains two pairs of probes - one for current supply and the other for the measurement of potential-drop, where the current-supply and measuring probes are in close proximity to each other. The optimum arrangement of the four-point-probes system is determined from the finite-element simulation of the three-dimensional electric crack problem. The predicted potential-drop across the crack has been verified experimentally using the newly developed measuring sensor. Measured results of semi-elliptical cracks in stainless steel plates establish the practicality as well as reliability of the present potential-drop method of testing for the evaluation of 3-D back-wall cracks in thick-walled structures.

本文言語English
ページ(範囲)434-440
ページ数7
ジャーナルKey Engineering Materials
321-323 I
出版ステータスPublished - 2006

ASJC Scopus subject areas

  • 材料科学(全般)
  • 材料力学
  • 機械工学

フィンガープリント

「DC potential-drop technique for the evaluation of 3-D back-wall cracks in steel structures」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル