Comparison of analytical estimation and 3-d measurement of all strands location in cic conductor

Daisuke Miyagi, Shinobu Nakazawa, Daichi Arai, Toshiya Morimura, Makoto Tsuda, Takataro Hamajima, Tsuyoshi Yagai, Norikiyo Koizumi, Yoshihiko Nunoya, Kazuya Takahata, Tetsuhiro Obana

研究成果: Article査読

4 被引用数 (Scopus)

抄録

It has been observed that the measured critical currents of cable-in-conduit-conductors (CICC) in some experiments are smaller than the expected ones. One of the reasons is the occurrence of unbalanced current at steady state caused by uneven contact resistances between strands. Because the contact resistance between strands is dependent on the contact length, the number of contacts and the loop length between strands, we need information about all strands' locations in the CICC. Therefore, we developed an evaluation method that describes the locations of every strand in the CICC in consideration of the twist disorder based on manufacture processes and elastic potential energy. Moreover, we compared the contact number and length between strands obtained by our calculated strands' positions with measured ones. We found that both results are in good agreement and clarified the validity of our calculation method of all strands' positions in the CICC.

本文言語English
論文番号6461070
ジャーナルIEEE Transactions on Applied Superconductivity
23
3
DOI
出版ステータスPublished - 2013

ASJC Scopus subject areas

  • 電子材料、光学材料、および磁性材料
  • 凝縮系物理学
  • 電子工学および電気工学

フィンガープリント

「Comparison of analytical estimation and 3-d measurement of all strands location in cic conductor」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル