Basic study on heat rejection system using high heat flux micro channel evaporator

研究成果: Article査読

1 被引用数 (Scopus)

抄録

Thermal management system which can reject very high amount of heat by small thermal devices will be required for future space systems. Our purpose is to develop miniaturized heat rejection system that can reject more than 100 W/cm2. In the evaporator, thin liquid film vaporization which can dissipate very high heat flux, was utilized. The liquid film is stabilized in micro-channels by capillary forces. The micro-channels are fabricated by chemical etching on silicon and copper plate. Also miniaturized condenser which utilized droplet condensation was tested. Droplets were produced on a cooled plate covered by non-wetting coating. After we built a heat rejection system constructed by above mentioned evaporator and condenser, influence of heat flux, coolant flow rate, and inlet temperature on the temperature of the heater element were investigated. Water is used as working fluid. Heat flux of 100 W/cm2 could be achieved for water inlet temperature in flow rate of 3.0 mL/min. The temperature of the heater element is kept constant at about 120°C.

本文言語English
ページ(範囲)30-32
ページ数3
ジャーナルMicrogravity Science and Technology
19
3-4
DOI
出版ステータスPublished - 2007 1 1

ASJC Scopus subject areas

  • Modelling and Simulation
  • Engineering(all)
  • Physics and Astronomy(all)
  • Applied Mathematics

フィンガープリント 「Basic study on heat rejection system using high heat flux micro channel evaporator」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。