TY - JOUR
T1 - Application of susceptibility weighted imaging (SWI) for evaluation of draining veins of arteriovenous malformation
T2 - Utility of magnitude images
AU - Miyasaka, Toshiteru
AU - Taoka, Toshiaki
AU - Nakagawa, Hiroyuki
AU - Wada, Takeshi
AU - Takayama, Katsutoshi
AU - Myochin, Kaoru
AU - Sakamoto, Masahiko
AU - Ochi, Tomoko
AU - Akashi, Toshiaki
AU - Kichikawa, Kimihiko
PY - 2012/11
Y1 - 2012/11
N2 - Introduction: The current study evaluated the signal characteristics of susceptibility weighted imaging (SWI) of arteriovenous malformation (AVM), especially for draining veins. For this purpose, we identified the draining veins of the AVM on angiography and evaluated the signal on magnitude image for SWI (SWI-mag) and minimum intensity projection image (SWI-minIP). Methods: Subjects were 14 cases with angiographically proven AVM. SWI-mag, SWI-minIP, and time-of-flight (TOF) magnetic resonance angiography were acquired. For the draining veins of the AVM identified on angiography, we analyzed signal intensity on the images listed above, and classified it into hyperintensity (hyper), mixed intensity (mixed), hypointensity (hypo), and no visualization. Results: On the analysis of 27 angiographically proven draining veins, 19 draining veins were classified as hyper, 3 as mixed, 0 as hypo, and 6 as no visualization on SWI-mag. On TOF images, 21 draining veins were classified as hyper, 2 as mixed, 0 as hypo, and 4 as no visualization, while 6 draining veins did not show hyperintensity on TOF, and SWI-mag visualized 3 of these 6 veins as hyper. Conclusion: SWI-mag depicted most draining veins of AVM as hyperintensity. We speculate that this is mainly due to the higher concentration of oxygenated hemoglobin (oxy-Hb) and inflow effect of the draining vein. SWI-mag seems to be useful in the analysis and follow-up for AVM as the signal on the image may reflect physiological status.
AB - Introduction: The current study evaluated the signal characteristics of susceptibility weighted imaging (SWI) of arteriovenous malformation (AVM), especially for draining veins. For this purpose, we identified the draining veins of the AVM on angiography and evaluated the signal on magnitude image for SWI (SWI-mag) and minimum intensity projection image (SWI-minIP). Methods: Subjects were 14 cases with angiographically proven AVM. SWI-mag, SWI-minIP, and time-of-flight (TOF) magnetic resonance angiography were acquired. For the draining veins of the AVM identified on angiography, we analyzed signal intensity on the images listed above, and classified it into hyperintensity (hyper), mixed intensity (mixed), hypointensity (hypo), and no visualization. Results: On the analysis of 27 angiographically proven draining veins, 19 draining veins were classified as hyper, 3 as mixed, 0 as hypo, and 6 as no visualization on SWI-mag. On TOF images, 21 draining veins were classified as hyper, 2 as mixed, 0 as hypo, and 4 as no visualization, while 6 draining veins did not show hyperintensity on TOF, and SWI-mag visualized 3 of these 6 veins as hyper. Conclusion: SWI-mag depicted most draining veins of AVM as hyperintensity. We speculate that this is mainly due to the higher concentration of oxygenated hemoglobin (oxy-Hb) and inflow effect of the draining vein. SWI-mag seems to be useful in the analysis and follow-up for AVM as the signal on the image may reflect physiological status.
KW - Arteriovenous malformation
KW - Magnetic resonance imaging
KW - Magnitude image
KW - Susceptibility weighted image
UR - http://www.scopus.com/inward/record.url?scp=84874428142&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84874428142&partnerID=8YFLogxK
U2 - 10.1007/s00234-012-1029-5
DO - 10.1007/s00234-012-1029-5
M3 - Article
C2 - 22592320
AN - SCOPUS:84874428142
VL - 54
SP - 1221
EP - 1227
JO - Neuroradiology
JF - Neuroradiology
SN - 0028-3940
IS - 11
ER -