We report the effects of implementing the list mode image reconstruction method (LMR) in a new brain scanner based on positron emission tomography. The benefits of LMR include reduced load in imaging processes and conservation of fine spatial data-sampling, the latter of which may be lost by data binning in histogram mode image reconstruction (HMR). In our project, we aim to build a high-spatialresolution scanner that employs three-dimensional positionsensitive CdTe semiconductor detector units. We experimentally confirmed that the unit could measure the detected positions of annihilation photons with a position resolution of 1 mm3 full width at half maximum (FWHM). Therefore, the scanner can potentially minimize the parallax-induced decrease in the spatial resolution of off-center positions in the field of view (FOV), thereby providing high resolution throughout the FOV because it obtains accurate depth of interaction (DOI) information at a sampling pitch ~1 mm finer than that of conventional DOI technologies (~4 mm). We simulated the proposed scanner. using the GEANT4 Application for Tomographic Emission. Reconstructed images were obtained by LMR or HMR based on the maximum likelihoodexpectation maximization (ML-EM) algorithm. The system matrix for ML-EM reconstruction was calculated by Siddon’s ray-driven method to fully exploit accurate detection positions. The spatial resolution at the center of the FOV acquired by LMR is 0.6 mm FWHM, which is superior to that acquired by HMR (1 mm FWHM). We confirmed that the resolutions of both methods are maintained at off-center positions, and the resolutions acquired by LMR at these positions are superior to those acquired by HMR. Furthermore, we simulated Hoffmanbrain- phantom imaging to evaluate the image quality of the scanner and LMR in human brain studies.

本文言語English
ホスト出版物のタイトルThe 15th International Conference on Biomedical Engineering, ICBME 2013
編集者James Goh
出版社Springer Verlag
ページ605-608
ページ数4
ISBN(電子版)9783319029122
DOI
出版ステータスPublished - 2014
イベント15th International Conference on Biomedical Engineering, ICBME 2013 - Singapore, Singapore
継続期間: 2013 12月 42013 12月 7

出版物シリーズ

名前IFMBE Proceedings
43
ISSN(印刷版)1680-0737

Other

Other15th International Conference on Biomedical Engineering, ICBME 2013
国/地域Singapore
CitySingapore
Period13/12/413/12/7

ASJC Scopus subject areas

  • バイオエンジニアリング
  • 生体医工学

フィンガープリント

「Application of list mode image reconstruction to fine DOI-PET scanner using position-sensitive CdTe semiconductor detector unit」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル