A novel analysis method for noise of perpendicular recording media

Wenli Pei, G. W. Qin, S. Ishio, Y. P. Ren, H. Saito, T. Washiya, K. Miura, H. Muraoka, F. Z. Lian, N. Honda

研究成果: Article査読

1 被引用数 (Scopus)

抄録

An in-field magnetic force microscopy (MFM) observation technology was introduced to study media noise in perpendicular recording medium. Magnetization reversal field (HR) distribution of the recording medium could be mapped by this technology. We have extracted media noise signal image from recording pattern. The noise signal image was converted to a contour image, in which peak areas represented high-noise areas. To clarify the relationship between HR distribution and the media noise, we novelly combined the contour with the HR-map. The results show that the media noise mostly gets generated in the lower-HR areas, which indicates the lower-HR area is one of the important origins of the media noise. For comparison, a simulation work was also performed by introducing a model based on experimental parameters. The simulation agreed with experimental results very well.

本文言語English
ページ(範囲)3165-3168
ページ数4
ジャーナルJournal of Magnetism and Magnetic Materials
320
22
DOI
出版ステータスPublished - 2008 11

ASJC Scopus subject areas

  • 電子材料、光学材料、および磁性材料
  • 凝縮系物理学

フィンガープリント

「A novel analysis method for noise of perpendicular recording media」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル