3-D FEM analysis of effect of twist pitch and shielding layer on multi-layered HTS power cable

Daisuke Miyagi, Norio Takahashi, Shinji Torii, Kiyotaka Ueda, Kenji Yasuda

研究成果: Article査読

8 被引用数 (Scopus)

抄録

3-D finite element analysis of current distribution taking account of the nonlinear E - J characteristic is carried out. In order to study the ac loss of multi-layered HTS power cable, the analysis region is considerably reduced by modeling spirally wound superconducting tapes as conductors having an anisotropic conductivity and using the periodic boundary condition. By using this model, the effect of the twist pitch on the current distribution of multi-layered HTS power cable with a shield layer is illustrated and the structure with low ac loss is discussed.

本文言語English
論文番号1643167
ページ(範囲)1614-1617
ページ数4
ジャーナルIEEE Transactions on Applied Superconductivity
16
2
DOI
出版ステータスPublished - 2006 6 1

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Electrical and Electronic Engineering