Temperature dependence of spectroscopic performance of thallium bromide X- and gamma-ray detectors

Toshiyuki Onoclera, Keitaro Hitomi, Taclayoshi Shoji

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)

Abstract

Thallium bromide (TlBr) is a compound semiconductor characterized by wide band-gap energy (2.68 eV), high atomic numbers (Tl: 81, Br: 35) and high density (7.56 g/cm3). Mobility-lifetime products for electrons ((μτ)e) and holes ((μτ)h) in TlBr crystals are 1 × 10-3 cm2/V and 3 × 10-4 cm2/V, respectively, which are comparable to μτ for carriers in CdTe crystals. Therefore, TlBr is a suitable material for fabrication of X- and gamma-ray detectors. In this study, TlBr detectors have been fabricated from crystals grown by the traveling molten zone method. The detectors have thicknesses of approximately 0.4 mm, and have gold electrodes (3 mm in diameter) on both surfaces of the crystals. In order to evaluate the temperature dependence of the charge transport properties of the detectors, (μτ) e and (μτ)h in the detectors have been estimated by the Hecht analysis at various temperatures of the detectors (-40,20,0,20 and 40°C). The (μτ)h in the detectors was of the order of 10-5 cm2/V at -40°C, and increased with increasing temperatures. The maximum value of the (μτ)h was obtained at 20°C, and was about ten times larger than the value at -40°C. On the other hand, the (μτ)e was approximately 1 × 10-3 cm 2/V between -40°C and 20°C. The temperature dependence of spectral response of the detectors has been evaluated by acquiring energy spectra of gamma-rays from 241Am at -40, 20, 0, 20 and 40°C. At -40°C, the full-energy peak corresponding to 59.5 keV gamma-rays has been obtained from the detectors, but the energy resolution of the peak was degraded due to the hole tailing on the low-energy side of the peak. The energy resolution of the detectors gradually improved with increasing temperatures of the detectors. The best FWHM energy resolution was measured to be 5.4 keV (9.1%) at 20°C.

Original languageEnglish
Pages (from-to)860-863
Number of pages4
JournalIEEE Transactions on Nuclear Science
Volume54
Issue number4
DOIs
Publication statusPublished - 2007 Aug 1

Keywords

  • Compound semiconductors
  • Gamma-ray detectors
  • Spectroscopic performance
  • Thallium bromide (TlBr)

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Nuclear Energy and Engineering
  • Electrical and Electronic Engineering

Fingerprint Dive into the research topics of 'Temperature dependence of spectroscopic performance of thallium bromide X- and gamma-ray detectors'. Together they form a unique fingerprint.

Cite this