Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

H. Abramowicz, A. Abusleme, K. Afanaciev, J. Aguilar, E. Alvarez, D. Avila, Y. Benhammou, L. Bortko, O. Borysov, M. Bergholz, I. Bozovic-Jelisavcic, E. Castro, G. Chelkov, C. Coca, W. Daniluk, L. Dumitru, K. Elsener, V. Fadeyev, M. Firlej, E. FiruT. Fiutowski, V. Ghenescu, M. Gostkin, H. Henschel, M. Idzik, A. Ishikawa, S. Kananov, S. Kollowa, S. Kotov, J. Kotula, D. Kozhevnikov, V. Kruchonok, B. Krupa, Sz Kulis, W. Lange, T. Lesiak, A. Levy, I. Levy, W. Lohmann, S. Lukic, C. Milke, J. Moron, A. Moszczynski, A. T. Neagu, O. Novgorodova, K. Oliwa, M. Orlandea, M. Pandurovic, B. Pawlik, T. Preda, D. Przyborowski, O. Rosenblat, A. Sailer, Y. Sato, B. Schumm, S. Schuwalow, I. Smiljanic, P. Smolyanskiy, K. Swientek, E. Teodorescu, P. Terlecki, W. Wierba, T. Wojton, S. Yamaguchi, H. Yamamoto, L. Zawiejski, I. S. Zgura, A. Zhemchugov

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.

Original languageEnglish
Article numberP05009
JournalJournal of Instrumentation
Volume10
Issue number5
DOIs
Publication statusPublished - 2015 May 1

Keywords

  • Calorimeters
  • Front-end electronics for detector readout

ASJC Scopus subject areas

  • Mathematical Physics
  • Instrumentation

Fingerprint Dive into the research topics of 'Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector'. Together they form a unique fingerprint.

  • Cite this

    Abramowicz, H., Abusleme, A., Afanaciev, K., Aguilar, J., Alvarez, E., Avila, D., Benhammou, Y., Bortko, L., Borysov, O., Bergholz, M., Bozovic-Jelisavcic, I., Castro, E., Chelkov, G., Coca, C., Daniluk, W., Dumitru, L., Elsener, K., Fadeyev, V., Firlej, M., ... Zhemchugov, A. (2015). Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector. Journal of Instrumentation, 10(5), [P05009]. https://doi.org/10.1088/1748-0221/10/05/P05009