Optimization of GFAG crystal surface treatment for SiPM based TOF PET detector

Han Gyu Kang, Kyoung Jin Kim, Kei Kamada, Akira Yoshikawa, Eiji Yoshida, Fumihiko Nishikido, Taiga Yamaya

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

Coincidence timing resolution (CTR) is an important parameter in clinical positron emission tomography (PET) scanners to increase the signal-to-noise ratio of PET images by using time-of-flight (TOF) information. Lutetium (Lu) based scintillators are often used for TOF-PET systems. However, the self-radiation of Lu-based scintillators may influence the image quality for ultra-low activity PET imaging. Recently, a gadolinium fine aluminum gallate (Ce:GFAG) scintillation crystal that features a fast decay time ( 1/455 ns) and no self-radiation was developed. The present study aimed at optimizing the GFAG crystal surface treatment to enhance both CTR and energy resolution (ER). The TOF-PET detector consisted of a GFAG crystal (3.0 × 3.0 × 20 mm3) and a SiPM with an effective area of 3.0 × 3.0 mm2. The timing and energy signals were extracted using a high-frequency SiPM readout circuit and then were digitized using a CAMAC DAQ system. The CTR and ER were evaluated with nine different crystal surface treatments such as partial saw-cut and chemical polishing and the 1-side saw-cut was the best choice among the treatments. The respective CTR and ER of 202 ± 2 ps and 9.5 ± 0.1% were obtained with the 1-side saw-cut; the other 5-side mechanically polished GFAG crystals had respective values which were 18 ps (9.0%) and 1.3% better than those of the all-side mechanically polished GFAG crystal. The chemically polished GFAG crystals also offered enhanced CTR and ER of about 17 ps (8.2%) and 2.1%, respectively, over the mechanically polished GFAG crystals.

Original languageEnglish
Article number025025
JournalBiomedical Physics and Engineering Express
Volume8
Issue number2
DOIs
Publication statusPublished - 2022 Mar

Keywords

  • GFAG crystal
  • SiPM
  • crystal surface treatment
  • positron emission tomography
  • time-of-flight

ASJC Scopus subject areas

  • Biophysics
  • Bioengineering
  • Biomaterials
  • Physiology
  • Biomedical Engineering
  • Radiology Nuclear Medicine and imaging
  • Computer Science Applications
  • Health Informatics

Fingerprint

Dive into the research topics of 'Optimization of GFAG crystal surface treatment for SiPM based TOF PET detector'. Together they form a unique fingerprint.

Cite this