The core loss measured with the indirect magnetizing single sheet tester (SST) (in which a sample is placed between yokes and is indirectly magnetized by the yokes magnetized by magnetizing coils) roughly corresponds with that measured with the direct magnetizing SST used as standard (in which a sample is placed inside a magnetizing coil and is directly magnetized by the magnetizing coil). Both the SSTs have the B coil and the H coil whose widths are the same as the sample width. However, the core loss measured with the indirect magnetizing SST using the small size of the B coil and the H coil is much different from that measured with the direct magnetizing SST.

Original languageEnglish
Pages (from-to)14-17
Number of pages4
JournalPrzeglad Elektrotechniczny
Volume83
Issue number4
Publication statusPublished - 2007 May 14

Keywords

  • Core loss
  • Electrical sheet
  • Magnetic measurement
  • Single sheet tester

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Fingerprint Dive into the research topics of 'Measurement of core loss in single sheet tester'. Together they form a unique fingerprint.