Abstract
Magnesium deoxidation equilibrium of molten Fe-Cr-Ni alloy was determined by a chemical equilibrium method at temperature of 1 873 to 1 973 K. Extreme care was taken of oxygen analysis of the samples. Numerical analysis on Mg deoxidation of molten Fe-Cr-Ni alloy has been carried out by utilizing the model based on Darken's quadratic formalism and Redlich-Kister type polynomial. Magnesium deoxidation equilibrium can be expressed in wide composition region of the Fe-Cr-Ni alloy.
Original language | English |
---|---|
Pages (from-to) | 895-900 |
Number of pages | 6 |
Journal | Isij International |
Volume | 51 |
Issue number | 6 |
DOIs | |
Publication status | Published - 2011 Jun 15 |
Keywords
- Activity
- Chromium
- Excess free Gibbs energy
- Iron
- Magnesium deoxidation equilibrium
- Nickel
- Quadratic formalism
- Redlich-Kister polynomial
- Thermodynamics
ASJC Scopus subject areas
- Mechanics of Materials
- Mechanical Engineering
- Metals and Alloys
- Materials Chemistry