Iron loss calculation by incorporating LLG equation into magnetic circuit model

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This paper presents an iron loss calculation by incorporating the Landau-Lifshitz-Gilbert (LLG) equation into a magnetic circuit model. In the proposed model, dc hysteresis loss is calculated by the LLG equation, and eddy current loss is calculated by a magnetic inductance. The validity is proved by comparing with the catalog values.

Original languageEnglish
Title of host publication2013 15th European Conference on Power Electronics and Applications, EPE 2013
DOIs
Publication statusPublished - 2013 Dec 17
Event2013 15th European Conference on Power Electronics and Applications, EPE 2013 - Lille, France
Duration: 2013 Sep 22013 Sep 6

Publication series

Name2013 15th European Conference on Power Electronics and Applications, EPE 2013

Other

Other2013 15th European Conference on Power Electronics and Applications, EPE 2013
CountryFrance
CityLille
Period13/9/213/9/6

Keywords

  • Hysteresis modeling
  • LLG equation
  • Magnetic circuit model
  • Simulation

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Fuel Technology
  • Electrical and Electronic Engineering

Fingerprint Dive into the research topics of 'Iron loss calculation by incorporating LLG equation into magnetic circuit model'. Together they form a unique fingerprint.

  • Cite this

    Tanaka, H., Nakamura, K., & Ichinokura, O. (2013). Iron loss calculation by incorporating LLG equation into magnetic circuit model. In 2013 15th European Conference on Power Electronics and Applications, EPE 2013 [6631860] (2013 15th European Conference on Power Electronics and Applications, EPE 2013). https://doi.org/10.1109/EPE.2013.6631860