Investigation of the radiation performance of CCD sensors in a vertex detector application

K. D. Stefanov, T. Tsukamoto, A. Miyamoto, Y. Sugimoto, N. Tamura, S. Takahashi, K. Abe, T. Nagamine, T. Aso

Research output: Contribution to journalConference article

4 Citations (Scopus)

Abstract

The radiation performance of a Hamamatsu S5466 and an EEV CCD02-06 silicon CCD sensors, working in a Multi-Pinned Phase (MPP) mode has been evaluated, in view of their possible use in the vertex detector of a future linear collider. We have examined the influence of the electron irradiation from a β-source with fluencies up to 4.3 × 1012 e-/cm2 on the parameters of the CCD sensors such as dark current, dark current spikes, drive pulse voltages and charge transfer inefficiency (CTI). The changes of the parameters of the devices resulting from the irradiation are reported and discussed.

Original languageEnglish
Pages (from-to)182-187
Number of pages6
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume436
Issue number1-2
DOIs
Publication statusPublished - 1999 Oct 21
EventProceedings of the 1998 7th International Conference on Solid State Detectors - Nara, Jpn
Duration: 1998 Dec 41998 Dec 6

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Fingerprint Dive into the research topics of 'Investigation of the radiation performance of CCD sensors in a vertex detector application'. Together they form a unique fingerprint.

  • Cite this