TY - JOUR
T1 - Four-dimensional measurement of the displacement of internal fiducial markers during 320-multislice computed tomography scanning of thoracic esophageal cancer
AU - Yamashita, Hideomi
AU - Kida, Satoshi
AU - Sakumi, Akira
AU - Haga, Akihiro
AU - Ito, Saori
AU - Onoe, Tsuyoshi
AU - Okuma, Kae
AU - Ino, Kenji
AU - Akahane, Masaaki
AU - Ohtomo, Kuni
AU - Nakagawa, Keiichi
PY - 2011/2/1
Y1 - 2011/2/1
N2 - Purpose: To investigate the three-dimensional movement of internal fiducial markers placed near esophageal cancers using 320-multislice CT. Methods and Materials: This study examined 22 metal markers in the esophageal wall near the primary tumors of 12 patients treated with external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. Results: Motion in the cranial-caudal (CC) direction showed a strong correlation (R2 > 0.4) with the respiratory curve in most markers (73%). The average absolute amplitude of the marker movement was 1.5 ± 1.6 mm, 1.6 ± 1.7 mm, and 3.3 ± 3.3 mm in the left-right (LR), anterior-posterior (AP), and CC directions, respectively. The average marker displacements in the CC direction between peak exhalation and inhalation for the 22 clips were 1.1 mm (maximum, 5.5 mm), 3.0 mm (14.5 mm), and 5.1 mm (16.3 mm) for the upper, middle, and lower thoracic esophagus, respectively. Conclusions: Motion in primary esophagus tumor was evaluated with 320-multislice CT. According to this study, 4.3 mm CC, 1.5 mm AP, and 2.0 mm LR in the upper, 7.4 mm CC, 3.0 mm AP, and 2.4 mm LR in the middle, and 13.8 mm CC, 6.6 mm AP, and 6.8 mm LR in the lower thoracic esophagus provided coverage of tumor motion in 95% of the cases in our study population.
AB - Purpose: To investigate the three-dimensional movement of internal fiducial markers placed near esophageal cancers using 320-multislice CT. Methods and Materials: This study examined 22 metal markers in the esophageal wall near the primary tumors of 12 patients treated with external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. Results: Motion in the cranial-caudal (CC) direction showed a strong correlation (R2 > 0.4) with the respiratory curve in most markers (73%). The average absolute amplitude of the marker movement was 1.5 ± 1.6 mm, 1.6 ± 1.7 mm, and 3.3 ± 3.3 mm in the left-right (LR), anterior-posterior (AP), and CC directions, respectively. The average marker displacements in the CC direction between peak exhalation and inhalation for the 22 clips were 1.1 mm (maximum, 5.5 mm), 3.0 mm (14.5 mm), and 5.1 mm (16.3 mm) for the upper, middle, and lower thoracic esophagus, respectively. Conclusions: Motion in primary esophagus tumor was evaluated with 320-multislice CT. According to this study, 4.3 mm CC, 1.5 mm AP, and 2.0 mm LR in the upper, 7.4 mm CC, 3.0 mm AP, and 2.4 mm LR in the middle, and 13.8 mm CC, 6.6 mm AP, and 6.8 mm LR in the lower thoracic esophagus provided coverage of tumor motion in 95% of the cases in our study population.
KW - Computed tomography
KW - Esophageal cancer
KW - Internal margin
KW - Intrafraction motion
UR - http://www.scopus.com/inward/record.url?scp=78650814437&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78650814437&partnerID=8YFLogxK
U2 - 10.1016/j.ijrobp.2010.03.045
DO - 10.1016/j.ijrobp.2010.03.045
M3 - Article
C2 - 20678869
AN - SCOPUS:78650814437
SN - 0360-3016
VL - 79
SP - 588
EP - 595
JO - International Journal of Radiation Oncology Biology Physics
JF - International Journal of Radiation Oncology Biology Physics
IS - 2
ER -