Five-year measurements of thermal performance for a semi-underground test house

H. Yoshino, S. Matsumoto, M. Nagatomo, T. Sakanishi

Research output: Contribution to journalArticlepeer-review

13 Citations (Scopus)

Abstract

In order to obtain fundamental data on the thermal performance of a semi-underground room, a twin-type test house was constructed on the campus of Tohoku University in September 1984. The test house has two rooms with south-facing windows above the ground surface, and a corridor between the two rooms. The floor level is 1.3m below the ground surface. Thermal insulation 0.1m deep and 1.35m wide was installed horizontally around the room on the east at a level 0.3m below the ground surface. The room on the west has no such "horizontal" insulation. Five-year measurements of air temperatures in both rooms, soil temperatures around the rooms, energy consumption for space heating, and so forth were made in four different situations. An experimental study found that horizontal insulation was effective in reducing the annual temperature fluctuation of indoor air, and in reducing the heating load. These effects, which were also analyzed from the viewpoint of heat balance in the room, were verified by computer calculations based on the two-dimensional finite element method.

Original languageEnglish
Pages (from-to)339-346
Number of pages8
JournalTunnelling and Underground Space Technology incorporating Trenchless
Volume7
Issue number4
DOIs
Publication statusPublished - 1992 Oct

ASJC Scopus subject areas

  • Building and Construction
  • Geotechnical Engineering and Engineering Geology

Fingerprint Dive into the research topics of 'Five-year measurements of thermal performance for a semi-underground test house'. Together they form a unique fingerprint.

Cite this