FEM analysis on the effects of soft magnetic film as a noise suppressor at GHz range

Ki Hyeon Kim, Shihji Ikeda, Masahiro Yamaguchi, Ken Ichi Arai

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

The finite element method (FEM) analysis on the effects of soft magnetic film as a noise suppressor at GHz range was discussed. It was found that the coplanar transmission line was with the total width of 400 μm and 50 μm width of signal line, 3 μm thickness respectively. The analysis showed that the change of the magnetic field distribution, the induced surface current density on the coplanar transmission line and hence the rf noise suppresson by magnetic films were significant as a function of the magnetic film width/slit width and magnetic film thickness.

Original languageEnglish
Pages (from-to)8588-8590
Number of pages3
JournalJournal of Applied Physics
Volume93
Issue number10 3
DOIs
Publication statusPublished - 2003 May 15

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Fingerprint Dive into the research topics of 'FEM analysis on the effects of soft magnetic film as a noise suppressor at GHz range'. Together they form a unique fingerprint.