Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians

Mime Endo, Yoshihiro Haga, Masahiro Sota, Akiko Tanaka, Kazuki Otomo, Yuuki Murabayashi, Mitsuya Abe, Yuji Kaga, Yohei Inaba, Msatoshi Suzuki, Taiichiro Meguro, Koichi Chida

Research output: Contribution to journalArticlepeer-review

Abstract

The new recommendation of the International Commission on Radiological Protection for occupational eye dose is an equivalent dose limit to the eye of 20 mSv year-1, averaged over a 5-year period. This recommendation is a drastic reduction from the previous limit of 150 mSv year-1. Hence, it is important to protect physicians' eyes from X-ray radiation. Particularly in interventional radiology (IVR) procedures, many physicians use protective lead (Pb) glasses to reduce their occupational exposure. This study assessed the shielding effects of novel 0.07 mm Pb glasses. The novel glasses (XR-700) have Pb-acrylic lens molded in three dimensions. We studied the novel type of 0.07 mm Pb glasses over a period of seven consecutive months. The eye dose occupational radiation exposure of seven IVR physicians was evaluated during various procedures. All IVR physicians wore eye dosimeters (DOSIRIS™) close to the left side of the left eye. To calculate the shielding effects of the glasses, this same type of eye dosimeter was worn both inside and outside of the Pb lenses. The average shielding effect of the novel glasses across the seven physicians was 61.4%. Our results suggest an improved shielding effect for IVR physicians that use these glasses. No physician complained that the new glasses were uncomfortable; therefore comfort is not a problem. The lightweight glasses were acceptable to IVR physicians, who often must perform long procedures. Thus, the novel glasses are comfortable and reasonably protective. Based on the results of this study, we recommend that IVR physicians use these novel 0.07 mm Pb glasses to reduce their exposure.

Original languageEnglish
Pages (from-to)414-419
Number of pages6
JournalJournal of radiation research
Volume62
Issue number3
DOIs
Publication statusPublished - 2021 May 12

Keywords

  • 3 mm dose equivalent [Hp(3)]
  • disaster medicine
  • eye lens dose
  • fluoroscopically guided procedures
  • interventional radiology (IVR)
  • Pb glasses (lead eyewear)
  • radiation disaster medicine
  • radiation safety
  • X-ray fluoroscopy

ASJC Scopus subject areas

  • Radiation
  • Radiology Nuclear Medicine and imaging
  • Health, Toxicology and Mutagenesis

Fingerprint

Dive into the research topics of 'Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians'. Together they form a unique fingerprint.

Cite this