Dry-contact technique for high-resolution ultrasonic imaging

Hironori Tohmyoh, Masumi Saka

Research output: Contribution to journalArticle

25 Citations (Scopus)

Abstract

To accomplish a high-resolution ultrasonic imaging without wetting a sample, the efficiency of the dry-contact ultrasonic transmission is discussed. In this study, a dry-contact interface is formed on a sample by inserting a thin film between water and a sample, and the pressure is working on the interface by evacuating the air between the film and the sample. A model of dry-contact ultrasonic transmission is presented to assess the signal loss accompanied with the transmission. From the determination of the signal loss caused by the transmission using various films, it was found that the higher frequency ultrasound is transmitted effectively into the sample by selecting an optimum film, which can keep the displacement continuity between the film and the sample during ultrasonic transmission. At last, ultrasonic imaging with the sufficient signal-to-noise ratio (SNR) and high lateral resolution was performed on the delamination in a package and the jointing interface of the ball-grid-array package without wetting the packages.

Original languageEnglish
Pages (from-to)661-667
Number of pages7
JournalIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Volume50
Issue number6
DOIs
Publication statusPublished - 2003 Jun 1

ASJC Scopus subject areas

  • Instrumentation
  • Acoustics and Ultrasonics
  • Electrical and Electronic Engineering

Fingerprint Dive into the research topics of 'Dry-contact technique for high-resolution ultrasonic imaging'. Together they form a unique fingerprint.