Double-sided microstrip sensor for the barrel of the SDC silicon tracker

T. Ohsugi, Y. Iwata, H. Ohyama, T. Ohmoto, M. Okada, N. Tamura, T. Hatakenaka, Y. Unno, T. Kohriki, F. Hinode, N. Ujiie, H. Miyata, K. Miyano, T. Aso, M. Daigo, A. Murakami, S. Kobayashi, R. Takashima, M. Higuchi, K. YamamotoK. Yamamura, M. Muramatsu, A. Seiden, H. Sadrozinski, Alex Grillo, N. Cartiglia, E. Barberis

Research output: Contribution to journalArticlepeer-review

23 Citations (Scopus)

Abstract

A full-size prototype microstrip sensor for the silicon tracker of the SDC detector to be used at the Superconducting Super Collider has been fabricated at Hamamatsu Photonics. The sensor is double-sided, using an AC-coupled readout with 50 μm pitch strips. The sensor size is 3.4 × 6.0 cm2. Polycrystalline silicon is used as a bias feeding resistor on both surfaces. Each ohmic strip is isolated by a p+ blocking line. The detailed requirements for the silicon tracker and the corresponding specifications as well as how to achieve them are discussed. The static performances of this prototype sensor are presented.

Original languageEnglish
Pages (from-to)16-21
Number of pages6
JournalNuclear Inst. and Methods in Physics Research, A
Volume342
Issue number1
DOIs
Publication statusPublished - 1994 Mar 15
Externally publishedYes

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Fingerprint

Dive into the research topics of 'Double-sided microstrip sensor for the barrel of the SDC silicon tracker'. Together they form a unique fingerprint.

Cite this