Development of Universal Robot Gripper Using MR α Fluid

Takeshi Nishida, Yuki Okatani, Kenjiro Tadakuma

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

In this paper, we developed a universal robot gripper using an electromagnet and a novel reforming magnetorheological (MR) fluid. First, we added nonmagnetic particles to an MR fluid to develop a novel reforming MR fluid called MRα fluid; this fluid resolved several issues faced with MR fluids. The developed fluid's specific gravity is one-half and solidification hardness is two times that of MR fluid. The characteristics of the MRα fluid and an application that can control solidification under a magnetic field are described. Next, the developed gripper, which consists of an electromagnet and an elastic membrane that encloses the MRα fluid, is described. Further, several experimental results of the features and capabilities of the gripper are presented.

Original languageEnglish
Article number1650017
JournalInternational Journal of Humanoid Robotics
Volume13
Issue number4
DOIs
Publication statusPublished - 2016 Dec 1

Keywords

  • Industrial robot
  • MR fluid
  • universal gripper

ASJC Scopus subject areas

  • Mechanical Engineering
  • Artificial Intelligence

Fingerprint Dive into the research topics of 'Development of Universal Robot Gripper Using MR α Fluid'. Together they form a unique fingerprint.