TY - JOUR
T1 - Determination of trace amounts of vanadium in air samples with 2-(8-quinolylazo)-5-N,N-diethylaminophenol by reversed-phase liquid chromatography
AU - Miura, Jun'ichiro
AU - Hoshino, Hitoshi
AU - Yotsuyanagi, Takao
PY - 1990
Y1 - 1990
N2 - A reversed-phase liquid chromatographic method for the determination of trace amounts of vanadium is described. Metal ions are converted into 2-(8-quinolylazo)-5-N,N-diethylaminophenol chelates in an off-line system. The chelates are injected onto a Zorbax CN column and separated with an aqueous acetonitrile mobile phase containing no chromogenic reagent. Unter these conditions, only vanadium(V) is spectrophotometrically detected at 540 nm among the metal ions Al(III), Ba(II), Ca(II), Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Ga(III), Hg(II), Mg(II), Mn(II), Ni(II), Pb(II), V(V) and Zn(II). Amounts of 8.0-200 pg of vanadium(V) in 100-μl injections can be determined without interference from 10-fold molar excesses of many cations. At 0.001 a.u.f.s., the detection limit (twice the peak-to-peak noise) for vanadium(V) is 8.0 pg in 100 μl of injected solution and the relative standard deviation at 120 pg of vanadium(V) in a 100-μl injection is 3.5%. The proposed method is applied to the determination of vanadium in rain water and airborne particulates.
AB - A reversed-phase liquid chromatographic method for the determination of trace amounts of vanadium is described. Metal ions are converted into 2-(8-quinolylazo)-5-N,N-diethylaminophenol chelates in an off-line system. The chelates are injected onto a Zorbax CN column and separated with an aqueous acetonitrile mobile phase containing no chromogenic reagent. Unter these conditions, only vanadium(V) is spectrophotometrically detected at 540 nm among the metal ions Al(III), Ba(II), Ca(II), Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Ga(III), Hg(II), Mg(II), Mn(II), Ni(II), Pb(II), V(V) and Zn(II). Amounts of 8.0-200 pg of vanadium(V) in 100-μl injections can be determined without interference from 10-fold molar excesses of many cations. At 0.001 a.u.f.s., the detection limit (twice the peak-to-peak noise) for vanadium(V) is 8.0 pg in 100 μl of injected solution and the relative standard deviation at 120 pg of vanadium(V) in a 100-μl injection is 3.5%. The proposed method is applied to the determination of vanadium in rain water and airborne particulates.
UR - http://www.scopus.com/inward/record.url?scp=0025326532&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025326532&partnerID=8YFLogxK
U2 - 10.1016/S0003-2670(00)83467-4
DO - 10.1016/S0003-2670(00)83467-4
M3 - Article
AN - SCOPUS:0025326532
VL - 233
SP - 121
EP - 127
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
SN - 0003-2670
IS - C
ER -