Corrosive effect of disinfection solution containing hydroxyl radicals generated by photolysis of H2O2 on dental metals

Keisuke Nakamura, Yasutomo Yamada, Yukyo Takada, Takayuki Mokudai, Hiroyo Ikai, Ryoichi Inagaki, Taro Kanno, Keiichi Sasaki, Masahiro Kohno, Yoshimi Niwano

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

The purpose of the present study was to evaluate the corrosive effect of disinfection solution containing hydroxyl radicals generated by photolysis of H2O2 on dental metals. Static immersion test was performed on four different dental metals: Ti, Type 316L stainless steel, Ag-Pd-Cu-Au alloy, and Co-Cr alloy. Metal specimens were immersed in 1 M H2O2 (=3.4%) with or without light-emitting diode (LED) light irradiation (wavelength: 400 nm) for 1 week, and then the amounts of released ions were analyzed. Corrosive effect of the disinfection solution containing hydroxyl radicals on any dental metals tested in the present study never exceeded that of H2O2 alone. Therefore, disinfection systems based on the photolysis of H2O2 for the cleaning of dentures and treatment of oral infectious diseases would not cause problematic metal corrosion whenever the concentration of H2O2 does not exceed 3%, which is a concentration used as an oral disinfectant.

Original languageEnglish
Pages (from-to)941-946
Number of pages6
JournalDental materials journal
Volume31
Issue number6
DOIs
Publication statusPublished - 2012

Keywords

  • Corrosion
  • Dental alloys
  • Hydrogen peroxide
  • Hydroxyl radical

ASJC Scopus subject areas

  • Ceramics and Composites
  • Dentistry(all)

Fingerprint Dive into the research topics of 'Corrosive effect of disinfection solution containing hydroxyl radicals generated by photolysis of H<sub>2</sub>O<sub>2</sub> on dental metals'. Together they form a unique fingerprint.

Cite this