CORROSION BEHAVIOURS OF INCONEL 617 COATED WITH SILICON OXIDE IN IMPURE HELIUM.

Yoshikazu Sakai, Tatsuo Shikama, Tatsuhiko Tanabe, Tadashi Suzuki

Research output: Contribution to journalConference articlepeer-review

Abstract

A heat resistant superalloy, constituting the heat exchanger of a high temperature gas cooled reactor (HTGR), will be corroded by impurities contained in the coolant helium gas. One side of Inconel 617 was coated with Si or SiO//x by reactive rf magnetron sputtering. Corrosion tests were conducted for 200 hours at 900 degree and 1000 degree C. The SiO//2 coating suppressed the development of oxidation.

Original languageEnglish
JournalTransactions of the Iron and Steel Institute of Japan
Volume24
Issue number6
Publication statusPublished - 1983 Jun 1
EventPrepr for the 106th ISIJ Meet, Pt 6 - Akita, Jpn
Duration: 1983 Oct 41983 Oct 6