TY - JOUR
T1 - Comparison of the intrusion effects on the maxillary incisors between implant anchorage and J-hook headgear
AU - Deguchi, Toru
AU - Murakami, Takashi
AU - Kuroda, Shingo
AU - Yabuuchi, Toshinori
AU - Kamioka, Hiroshi
AU - Takano-Yamamoto, Teruko
PY - 2008/5
Y1 - 2008/5
N2 - Introduction: Recently, miniscrews have been used to provide anchorage during orthodontic treatment, especially for incisor intrusion. Miniscrews during incisor intrusion are commonly used in implant orthodontics. Traditionally, effective incisor intrusion has been accomplished with J-hook headgear. In this study, we compared the effect of incisor intrusion, force vector, and amount of root resorption between implant orthodontics and J-hook headgear. Methods: Lateral cephalometric radiographs from 8 patients in the implant group and 10 patients in the J-hook headgear group were analyzed for incisor retraction. The estimated force vector was analyzed in the horizontal and vertical directions in both groups. Root resorption was also measured on periapical radiographs. Results: In the implant group, significant reductions in overjet, overbite, maxillary incisor to palatal plane, and maxillary incisor to upper lip were observed after intrusion of the incisors. In the J-hook headgear group, significant reductions in overjet, overbite, maxillary incisor to upper lip, and maxillary incisor to SN plane were observed after intrusion of the incisors. There were significantly greater reductions in overbite, maxillary incisor to palatal plane, and maxillary incisor to upper lip in the implant group than in the J-hook headgear group. Estimated force analysis resulted in significantly more force in the vertical direction and less in the horizontal direction in the implant group. Furthermore, significantly less root resorption was observed in the implant group compared with the J-hook headgear group. Conclusions: The maxillary incisors were effectively intruded by using miniscrews as orthodontic anchorage without patient cooperation. The amount of root resorption was not affected by activating the ligature wire from the miniscrew during incisor intrusion.
AB - Introduction: Recently, miniscrews have been used to provide anchorage during orthodontic treatment, especially for incisor intrusion. Miniscrews during incisor intrusion are commonly used in implant orthodontics. Traditionally, effective incisor intrusion has been accomplished with J-hook headgear. In this study, we compared the effect of incisor intrusion, force vector, and amount of root resorption between implant orthodontics and J-hook headgear. Methods: Lateral cephalometric radiographs from 8 patients in the implant group and 10 patients in the J-hook headgear group were analyzed for incisor retraction. The estimated force vector was analyzed in the horizontal and vertical directions in both groups. Root resorption was also measured on periapical radiographs. Results: In the implant group, significant reductions in overjet, overbite, maxillary incisor to palatal plane, and maxillary incisor to upper lip were observed after intrusion of the incisors. In the J-hook headgear group, significant reductions in overjet, overbite, maxillary incisor to upper lip, and maxillary incisor to SN plane were observed after intrusion of the incisors. There were significantly greater reductions in overbite, maxillary incisor to palatal plane, and maxillary incisor to upper lip in the implant group than in the J-hook headgear group. Estimated force analysis resulted in significantly more force in the vertical direction and less in the horizontal direction in the implant group. Furthermore, significantly less root resorption was observed in the implant group compared with the J-hook headgear group. Conclusions: The maxillary incisors were effectively intruded by using miniscrews as orthodontic anchorage without patient cooperation. The amount of root resorption was not affected by activating the ligature wire from the miniscrew during incisor intrusion.
UR - http://www.scopus.com/inward/record.url?scp=43049141886&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=43049141886&partnerID=8YFLogxK
U2 - 10.1016/j.ajodo.2006.04.047
DO - 10.1016/j.ajodo.2006.04.047
M3 - Article
C2 - 18456138
AN - SCOPUS:43049141886
VL - 133
SP - 654
EP - 660
JO - American Journal of Orthodontics and Dentofacial Orthopedics
JF - American Journal of Orthodontics and Dentofacial Orthopedics
SN - 0889-5406
IS - 5
ER -